Gas Leak Detection And Repair In Northern California
Valley Oaks Elementary, Galt California - Gas Line Replacement
MBS Engineering, working as a subcontractor for a larger Modernization project, replaced the aging and undersized gas system in place at Valley Oaks Elementary in Galt, CA during the summer of 2018. Not only did MBS crews install over 400 LF of 6” MDPE gas piping all to PG&E standards and procedures, but also made connections to 6 existing branch lines feeding the school, installed important isolation valves at each building connection, installed a new 6” Manual Shut-Off Valve downstream of the Utility Gas Meter, and installed a new 6” Seismic Shut-Off Valve to protect the school from gas fires or explosions during a seismic event. MBS PG&E certified welding crews fabricated the connection to the existing gas meter and tie-in to the underground gas line route following all PG&E standards and procedures for steel pipe welding.
The project itself was a last minute, short notice project and a very short window of completion was given for MBS to complete the work. Working long hours and even weekends, MBS was able to complete the project ahead of schedule, making the school district and Prime Contractor ecstatic with the work performed. MBS' total scope of work included Professional Utility Locating, Asphalt & Concrete Cutting and Removal, Excavation/Trenching, Underground Pipe Installation, Utility Gas Meter Tie-In, Seismic Shut-Off Valve Installation, Pressure & Leak Testing, Backfill of the Gas Line Trench, and Asphalt/Concrete patch back. The gas was turned back on to the school 2.5 weeks after MBS arrived on site, a full week ahead of schedule.
The project itself was a last minute, short notice project and a very short window of completion was given for MBS to complete the work. Working long hours and even weekends, MBS was able to complete the project ahead of schedule, making the school district and Prime Contractor ecstatic with the work performed. MBS' total scope of work included Professional Utility Locating, Asphalt & Concrete Cutting and Removal, Excavation/Trenching, Underground Pipe Installation, Utility Gas Meter Tie-In, Seismic Shut-Off Valve Installation, Pressure & Leak Testing, Backfill of the Gas Line Trench, and Asphalt/Concrete patch back. The gas was turned back on to the school 2.5 weeks after MBS arrived on site, a full week ahead of schedule.
Solano Community College
MBS Engineering worked as prime contractor to replace over 4,000 linear feet of gas line around the Solano Community College campus. MBS also installed new gas pressure regulators and submeters at many of the buildings.
Bellevue Union School District - Gas Leak Surveys
MBS Engineering worked with the Bellevue Union School District in Sonoma County, CA to conduct gas leak surveys at all the campuses in their district. These gas leak surveys covered 4 schools and provided the school district with valuable information on potential dangers and how to address them.
Our ProcessMBS Engineering utilizes utility-grade leak detection equipment manufactured by Heath Consultants USA -- the same equipment used by your local utility companies. MBS employs fully trained and certified technicians to perform all Gas Leak Surveys. Some other aspects of our gas leak detection service include:
|
Experts at Detecting and Repairing leaksOur team is focused on innovation and ensures our field technicians have the latest technology to produce the most reliable surveys possible. We have an excellent track record with hospitals, universities, public schools, commercial clients and California utilities. With our extensive experience, professional field officers and state-of-the-art equipment, we're able to provide the most efficient and reliable gas leak detection possible. You can depend on our experts to help keep your gas system and your facility safe.
|